Installation Procedure
- Install the CMP sensor and bolt.
Tighten: Tighten the CMP sensor bolts to 7 N.m (62 lb in) .
- Install the timing bolt front cover. Refer to Timing Belt Replacement .
- Connect the CMP sensor electrical connector.
- Install the engine cover.
- Connect the negative battery cable.
NOTE:
Refer to Fastener Notice
.