LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Chevrolet >> 2009 >> Traverse AWD V6-3.6L >> Repair and Diagnosis >> Testing and Inspection >> Programming and Relearning >> Liftgate Calibration Procedure
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Liftgate Calibration Procedure




Liftgate Calibration

Important: To ensure proper calibration of the liftgate, the liftgate assembly must be at room temperature during calibration.


Conditions

Use this procedure after replacing, repairing, or disassembling any portion of the power liftgate assembly.

Calibrate Liftgate
1. Connect the Tech 2 to the vehicle.
2. Select Special Functions in the Liftgate Module menu.
3. Select LGM Open/Close Test.
4. Follow the on screen instructions.