Installation Procedure
CAUTION:
Refer to Fastener Caution
.
NOTE:
DO NOT apply thread sealant to the sensor threads. The sensor threads are coated at the factory. Applying additional sealant affects the sensors ability to detect detonation.
- Install and tighten the knock sensor (1).
Tighten: Tighten the sensor to 25 N.m (18 lb ft).
- Connect the knock sensor electrical connector (1).
- Install the catalytic converter. Refer to Catalytic Converter Replacement (LZ4, LZE, or LGD) .
- Lower the vehicle.