Installation Procedure
- Position the NEW fuel sender O-ring seal onto the fuel tank.
- Install the fuel sender (2) into the fuel tank. Ensure that the align tab is in the proper location.
- Push down the fuel sender and position the lock ring (1) onto the fuel tank.
- Use the J 45722 in order to install the fuel sender lock ring. Turn the fuel sender lock ring in a clockwise direction.
- Connect the fuel line to the sender. Refer to Metal Collar Quick Connect Fitting Service .
- Connect the EVAP lines to the sender. Refer to Plastic Collar Quick Connect Fitting Service .
- Install the fuel tank. Refer to Fuel Tank Replacement .
NOTE:
Always replace the fuel sender seal when installing the fuel sender assembly. Replace the lock ring if necessary. Do not apply any type of lubrication in the seal groove.
Ensure the lock ring is installed with the correct side facing upward. A correctly installed lock ring will only turn in a clockwise direction.
Ensure the lock ring is installed with the correct side facing upward. A correctly installed lock ring will only turn in a clockwise direction.