Installation Procedure
- Install the air inlet duct from the MAF/IAT sensor.
- Tighten the air inlet duct clamp at the MAF/IAT sensor.
Tighten: Tighten the clamp to 3 N.m (27 lb in).
- Install the air inlet duct to the throttle body.
- Tighten the air inlet duct clamp at the throttle body.
Tighten: Tighten the clamp to 3 N.m (27 lb in).
- Connect the PCV tube to the air inlet duct. Refer to Plastic Collar Quick Connect Fitting Service .
CAUTION:
Refer to Fastener Caution
.