Circuit/System Testing
- Ignition OFF, disconnect the harness connector at the shift lock control solenoid.
- Ignition OFF, test for less than 30 Ω between the appropriate connector terminal listed below and ground:
- Floor shift - terminal A
- Column shift - terminal B
- If greater than the specified range, test the ground circuit for an open/high resistance.
- Install a test lamp between connector terminal A and terminal B.
- Ignition ON, command the scan tool BCM Shift Lock Solenoid output control ON and OFF. The test lamp should turn ON and OFF as commanded.
- If the test lamp is always ON, test the control circuit for short to voltage. If the circuit tests normal, replace the BCM.
- If the test lamp is always OFF, test the control circuit for short to ground or an open/high resistance. If the circuit tests normal, replace the BCM.
- If the circuit tests normal, test or replace the shift lock control solenoid.