Circuit/System Testing
P0D43 or P0D44
- Vehicle OFF and all vehicle systems OFF. It may take up to 2 minutes for all vehicle systems to power down. Disconnect the X1 harness connector at the T18 Battery Charger.
- Vehicle ON.
- Test for greater than 12 V DC between the ignition circuit terminal A and ground.
- If less than 12 V
- Vehicle OFF and all vehicle systems OFF. It may take up to 2 minutes for all vehicle systems to power down. Disconnect the X2 harness connector at the T18 Battery Charger.
- Test for infinite resistance between the B+ circuit terminal 2 and ground.
- If less than infinite resistance, repair the short to ground on the circuit.
- If infinite resistance, replace the T18 Battery Charger.
- If 12 V or greater
- Replace the T18 Battery Charger.
P0D45
Replace the T18 Battery Charger.