Installation Procedure
- Install a NEW O-ring (3) to the CMP sensor.
- Install the CMP sensor (2) to the engine front cover.
- Install the CMP sensor to engine front cover retaining bolt (1) and tighten to 9 (80 lb in).
- Connect the CMP sensor electrical connector (1) to wiring harness.
- Install the air cleaner outlet duct. Refer to Air Cleaner Outlet Duct Replacement .
- Connect the battery ground cable to the battery. Refer to Battery Negative Cable Disconnection and Connection .
- If re-programming is required, refer to Control Module References .
NOTE:
Install a NEW O-ring to the camshaft sensor
NOTE:
Before installing the camshaft sensor, apply a small amount of clean motor oil to the O-ring (3).
CAUTION:
Refer to Fastener Caution .