Fuel Tank Draining
WARNING:
Refer to Gasoline/Gasoline Vapors Warning .
WARNING:
Refer to Safety Goggles and Fuel Warning .
WARNING:
Refer to .
- Disconnect the negative battery cable. Refer to Battery Negative Cable Disconnection and Connection .
- Remove the fuel tank filler cap.
- Insert a suitable suction hose into the fuel tank filler pipe.
- Attach a suitable suction hose to the hose used with the hand or air operated pump devise.
- Using a hand or air operated pump drain as much fuel from the tank as possible.
NOTE:
The fuel tank must be drained with a suitable, commercially-available fuel removal unit and suction hose - follow safety regulations and national legislation. The fuel tank is fitted with a refill limit float valve. This is located on the filler neck in the fuel tank. To prevent damaging the refill limit float valve, a suitable suction hose must be used. In the presence of fuel vapors or escaping fuel - observe safety regulations and national legislation. Store drained fuel in a suitable, sealable container.