Circuit/System Verification
- Engine running.
- Verify the scan tool Rear Defogger Switch parameter changes between On and Off when pressing the rear window defogger switch.
- If the parameter does not change between On and Off
Replace the A26 HVAC controls.
- If the parameter changes between On and Off
- If the parameter does not change between On and Off
- Verify the E18 Rear Defogger Grid turns ON and OFF when commanding the Rear Defogger On and Off with a scan tool.
- If the E18 Rear Defogger Grid does not turn ON and OFF
Refer to Circuit/System Testing
- If the E18 Rear Defogger Grid turns ON and OFF
- If the E18 Rear Defogger Grid does not turn ON and OFF
- Verify the rear defogger indicator turns ON and OFF when pressing the rear window defogger switch.
- If the rear defogger indicator does not turn ON and OFF
Replace the A26 HVAC controls.
- If the rear defogger indicator turns ON and OFF
- If the rear defogger indicator does not turn ON and OFF
- All OK.