  1. Vehicle OFF and all vehicle systems OFF. Disconnect the X2 harness connector at the X98 Hybrid/EV Battery Charger Receptacle. It may take up to 2 min for all vehicle systems to power down.
  2. Test for less than 10 Ω between the low reference terminal 6 and ground.
    • If 10 Ω or greater 
    1. Vehicle OFF, disconnect the X2 harness connector at the K114B Hybrid/EV Powertrain Control Module 2.
    2. Test for less than 2 Ω in the low reference circuit end to end.
      • If 2 Ω or greater, repair the open/high resistance in the circuit
      • If less than 2 Ω, replace the K114B Hybrid/EV Powertrain Control Module 2.
    • Go to next step: If less than 10 Ω 
  3. Vehicle in Service Mode.
  4. Test for 4.8 - 4.95 V between the signal circuit terminal 5 and ground.
    • If less than 4.8 V 
    1. Vehicle OFF, disconnect the X2 harness connector at the K114B Hybrid/EV Powertrain Control Module 2.
    2. Test for infinite resistance between the signal circuit and ground
      • If less infinite resistance, repair the short to ground on the circuit.
      • Go to next step: If infinite resistance
    3. Test for less than 2 Ω in the signal circuit end to end.
      • If 2 Ω or greater, repair the open/high resistance in the circuit
      • If less than 2 Ω, replace the K114B Hybrid/EV Powertrain Control Module 2.
    • If greater than 4.95 V 
    1. Vehicle OFF, disconnect the X2 harness connector at the K114B Hybrid/EV Powertrain Control Module 2. Vehicle in Service Mode.
    2. Test for less than 1 V between the signal circuit and ground.
      • If between 1 - 5.2 V, repair the short to voltage on the circuit.
      • If greater than 5.2 V, repair the short to voltage on the circuit and replace the X98 Hybrid/EV Battery Charger Receptacle.
      • If less than 1 V, replace the K114B Hybrid/EV Powertrain Control Module 2.
    • Go to next step: If between 4.8 - 4.95 V 
  5. Replace the X98 Hybrid/EV Battery Charger Receptacle.