Component Testing
- Vehicle OFF and all vehicle systems OFF. Disconnect the X2 harness connector at the X98 Hybrid/EV Battery Charger Receptacle.
- Test for 2.76 - 2.93k Ω at approximately 25°C (77°F) between the signal terminal 5 and the low reference terminal 6.
- If not within the specified range
Replace the X98 Hybrid/EV Battery Charger Receptacle.
- Go to next step: If within the specified range
- If not within the specified range
- All OK.