Excessive Fuel Flow
- With air cleaner cover removed, turn key on. If fuel flows continuously from injectors, disconnect control pump connector.
- If fuel continues to flow, replace fuel control plate (pump, injectors, flowmeter).
- If fuel flow stops, problem is in computer. Substitute good computer and retest. If original proves defective, replace computer.