The logic module controls the purge and EGR solenoids. When engine temperature reaches 145°F (61°C), the logic module de-energizes the purge solenoid. When de-energized, ported vacuum flows to canister purge valve and fuel vapors vent to throttle body.
The EGR solenoid is operated in the same manner when engine temperature reaches 70°F (21°C). No EGR occurs during idle or wide open throttle.