Failure To Start Test 3.3L
- Ensure sufficient battery voltage is available to operate cranking and ignition systems. Connect voltmeter between B+ wiring harness coil connector and ground.
- Crank engine for 5 seconds while monitoring voltage at B+ terminal. If voltage remains near zero during entire period of cranking, see appropriate SELF-DIAGNOSTICS article to check SBEC and ASD relay.
- If voltage is near battery voltage and drops to zero after 1-2 seconds of cranking, see appropriate SELF-DIAGNOSTICS article to check cam and crank sensor circuits to SBEC.
- If voltage remains near battery voltage during entire 5 seconds, turn ignition off. Disconnect SBEC 60-pin connector. Check 60-pin connector for loose terminals (push-outs).