Test 15A - Electronic Instrument Cluster Diagnostics

NOTE: For connector terminal identification, see CONNECTOR IDENTIFICATION  . For appropriate wiring diagram, see WIRING DIAGRAMS  at end of article. Powertrain Control Module (PCM).
  1. Turn ignition on. Using DRB-II, select ELECTRONIC CLUSTER module. If DRB-II displays NO RESPONSE, go to TEST 94A  . If DRB-II does not display NO RESPONSE, turn ignition on (engine off).
  2. Using DRB-II, read electronic instrument cluster faults. If DRB-II displays 01 NO BUS ACTIVITY or 02 NO MESSAGE FROM BODY CONTROLLER, go to TEST 93A  .
  3. If DRB-II displays 04 NO MESSAGE FROM ENGINE CONTROLLER, go to TEST 97A  . If DRB-II displays 08 BUS LOOP FAILURE or 40 POWER SUPPLY SHORT CIRCUIT, replace electronic instrument cluster. Perform VERIFICATION PROCEDURE VER-1.
  4. If DRB-II displays 10 DISPLAY DRIVER CIRCUITRY FAILURE or 20 MICROCOMPUTER INTERNAL FAILURE, replace electronic instrument cluster. Perform VERIFICATION PROCEDURE VER-1.
  5. If DRB-II displays 80 BODY COMPUTER ODOMETER FAILURE, replace Body Control Module (BCM). BCM is located behind right side kick panel. Perform VERIFICATION PROCEDURE VER-1.
  6. If DRB-II does not display any fault code, identify problem area(s) listed in ELECTRONIC INSTRUMENT CLUSTER PROBLEM table and perform the indicated test(s). Diagnosis of electronic instrument cluster is broken down into 8 areas.
ELECTRONIC INSTRUMENT CLUSTER PROBLEM

Problem Perform Test No.
Blank Cluster Diagnosis 15B 
Gauge Diagnosis 16A 
Odometer Diagnosis 18A 
Speedometer Diagnosis 18B 
Diagnosis Of Any Or All Warning Lights 19A 
Cluster Illumination Diagnosis 22A 
Cluster Illumination Diagnosis Upon Entry 23A 
Cluster Switch Diagnosis 24A