Test 83B - Trunk Key Cylinder Sense Switch
NOTE:
For connector terminal identification, see CONNECTOR IDENTIFICATION
. For appropriate wiring diagram, see WIRING DIAGRAMS
at end of article.
- Disconnect trunk key cylinder sense switch. Using DRB-II, read trunk key cylinder sense switch status. If DRB-II does not display CIRCUIT CLOSED, go to TEST 92A .
- If DRB-II displays CIRCUIT CLOSED, turn ignition off. Disconnect Vehicle Theft Alarm (VTA) module. See Figure . With DRB-II in ohmmeter mode, check resistance on terminal No. 19 (Violet/Yellow wire) of VTA module connector.
- If resistance is less than 5 ohms, repair short to ground in Violet/Yellow wire. Perform VERIFICATION PROCEDURE VER-1. If resistance is more than 5 ohms, replace VTA module. Perform VERIFICATION PROCEDURE VER-1.