Test 7E - Short To Battery
NOTE:
For connector terminal identification, see CONNECTOR IDENTIFICATION
. For wiring diagram, see WIRING DIAGRAMS
. After each repair, perform TEST VER-1.
Using DRB in ohmmeter mode, check resistance of instrument cluster connector terminal No. 7 (Black/Light Green wire). If resistance is more than 5 ohms, repair open in Black/Light Green wire. If resistance is less than 5 ohms, replace MIC or EIC.