System Precautions
CAUTION:
See the ANTI-LOCK BRAKE SAFETY PRECAUTIONS
article in the GENERAL INFORMATION section.
Before proceeding with diagnosis, read and observe following precautions:
- Ensure battery is fully charged and charging system is functional.
- Probe Controller Anti-Lock Brake (CAB) connector from pin side. DO NOT backprobe CAB connector. Probe connector terminal carefully. DO NOT spread terminal, as this could cause intermittent problem.
- When using a jumper wire, ensure either the jumper wire or circuit is fuse-protected.
- DO NOT cause short circuits when performing electrical tests. This will set additional fault messages, making diagnosis of original problem more difficult.
- DO NOT unplug or plug CAB connector with ignition on.
- Use scan tool voltmeter unless instructed to use external voltmeter.
- DO NOT use test light in place of voltmeter.
- Use scan tool ohmmeter unless instructed to use external ohmmeter.
- Always perform TEST VER-1A under SELF-DIAGNOSTIC TESTS after repairs are made.
- Always disconnect scan tool when done.
- Always disconnect scan tool before charging battery.