A Bosch permanent magnet gear reduction starter is used on some 3.0L V6 engines. Bosch starters use a planetary gear train that transmits power from starter motor to pinion shaft. Six permanent magnets are used, eliminating potential field wire-to-frame shorts. A Nippondenso field coil gear reduction starter is used on some 3.0L V6 engines.

LeBaron Cconvertible uses a starter relay in starter circuit between the battery and starter solenoid terminal. Automatic Transmission (A/T) equipped vehicles use a neutral safety switch to provide ground path for the starter relay. Manual Transmission (M/T) equipped vehicles use a clutch pedal interlock switch to provide battery voltage from ignition switch to the starter relay. See Fig 1.

Fig 1: Starter Circuit (LeBaron Convetible)
G92A03640Courtesy of CHRYSLER CORP.