Test 26A - Instrument Cluster Problems Not Covered By Trouble Codes
NOTE:
Perform TEST VER-1 after each repair.
Using scan tool, select EIC SEQUENTIAL SEGMENTS test. If any segments of instrument cluster fail to illuminate or 2 segments illuminate at the same time (test fails), replace instrument cluster. If test passes, identify faulty area of instrument cluster and perform corresponding test in INSTRUMENT CLUSTER PROBLEMS table.
INSTRUMENT CLUSTER PROBLEMS
| Problem | Perform Test | ||
|---|---|---|---|
| Temperature Gauge | TEST 27A | ||
| Fuel Gauge | TEST 121A | ||
| Oil Gauge | TEST 122A | ||
| Voltage Gauge | (1) * | ||
|
|||