Test 92A - Both Doors Fail To Lock From One Switch
CAUTION:
Always turn ignition off prior to disconnecting or connecting any module connector.
NOTE:
For connector terminal identification, see CONNECTOR IDENTIFICATION . For wiring diagram, see WIRING DIAGRAMS - 3.0L
article in ENGINE PERFORMANCE. Perform TEST VER-1 after each repair.
- Lower both front windows. Remove key from ignition. Gain access to inoperative door lock switch. Disconnect inoperative door lock switch connector. Go to next step.
- Using scan tool in voltmeter mode, check voltage on inoperative door lock switch connector terminal No. 1 (Orange/Violet wire). Depress opposite door lock switch to LOCK position while observing scan tool display. If voltage is less than 9 volts when door lock switch is replaced, repair open Orange/Violet wire. If voltage is more than 9 volts, replace inoperative door lock switch.