Test 102D - Programming RKE Transmitter
NOTE:
For connector terminal identification and wiring diagrams, see BODY CONTROL COMPUTER
section in this article. Perform TEST VER-1
VERIFICATION TEST after each repair.
CAUTION:
Always turn ignition off prior to disconnecting any module connector.
- When RKE module is put in programming mode, all transmitters that will be used must be programmed. Ensure transmitter(s) have good batteries. Go to next step.
- Using scan tool, select PROGRAM RKE under MISCELLANEOUS. If door locks cycle, go to next step. This indicates that module is in programming mode. If door do not cycle, inspect enable circuit. Repair as needed. If enable circuit is okay, replace RKE module.
- Press any button on transmitter. Locks will cycle. Press any button on additional transmitter (if applicable). Locks will cycle. Exit PROGRAM RKE on scan tool. Turn ignition off.