Test 102E - Remote Keyless Entry Problem

NOTE: For connector terminal identification and wiring diagrams, see BODY CONTROL COMPUTER  section in this article. Perform TEST VER-1  VERIFICATION TEST after each repair.
CAUTION: Always turn ignition off prior to disconnecting any module connector.
  1. Gain access to the Remote Keyless Entry (RKE) module. See Figure . Turn ignition off and remove key. Disconnect RKE module Black connector. Turn ignition on. Go to next step.
  2. Using scan tool in voltmeter mode, check voltage on RKE module Black connector terminal "A" (Pink wire). If voltage is 10 volts or less, repair open Pink wire. If voltage is more than 10 volts, go to next step.
  3. Using scan tool in ohmmeter mode, check resistance of RKE module Black connector terminal "D" (Dark Green wire). If resistance is 1500 ohms or less, repair short to ground in Dark Green wire. If resistance is more than 1500 ohms, go to next step.
  4. Using scan tool in voltmeter mode, check voltage on RKE module Black connector terminal "G" (Pink/Black wire). Press and hold door lock switch in LOCK position. If voltage is 10 volts or less, repair open Pink/Black wire. If voltage is more than 10 volts, go to next step. Release door lock switch.
  5. Check voltage on RKE module Black connector terminal "E" (Pink/Violet wire). Press and hold door lock switch in UNLOCK position. If voltage is 10 volts or less, repair open Pink/Violet wire. If voltage is more than 10 volts, go to next step. Release door lock switch.
  6. Check voltage on RKE module Black connector terminal "C" (Orange/White wire). Press and hold door lock switch in LOCK position. If voltage is 10 volts or less, repair open Orange/White wire. If voltage is more than 10 volts, replace RKE module.