Automatic (Rolling) Door Locks Inoperative
NOTE:
After making any repairs, perform BODY VERIFICATION TEST
under VERIFICATION TESTS.
Possible Causes:
- Check The Door Ajar Switch Status
- With The Scan Tool Check For PCM DTC's
- With The Scan Tool Enable Auto Door Locks
- Body Control Module
Testing
- Turn ignition off. Connect scan tool to Data Link Connector (DLC). Close all doors. Using scan tool, read DOOR AJAR status. If scan tool displays CLOSED for any door, perform appropriate DOOR AJAR CKT STG test under DOOR AJAR SYSTEM . If scan tool displays OPEN for all door, go to next step.
- Using scan tool, retrieve Powertrain Control Module (PCM) DTCs. If no PCM DTCs exist, go to next step. If any PCM DTCs exist, see SELF-DIAGNOSTICS - CONCORDE, INTREPID & 300M article in ENGINE PERFORMANCE.
- Using scan tool, read AUTO DOOR LOCK status. If scan tool displays ENABLED, replace BCM. See BODY CONTROL MODULE under REMOVAL & INSTALLATION. If scan tool does not display ENABLED, enable auto door locks using scan tool.