Standard Procedure - Quick Connect Fittings: Removal
When disconnecting a quick-connect fitting, the retainer will remain on the fuel tube nipple.
WARNING:
RELEASE FUEL SYSTEM PRESSURE BEFORE DISCONNECTING A QUICK-CONNECT FITTINGS. REFER TO STANDARD PROCEDURE - FUEL SYSTEM PRESSURE RELEASE PROCEDURE .
- Perform Fuel Pressure Release Procedure. Refer to the STANDARD PROCEDURE - FUEL SYSTEM PRESSURE RELEASE PROCEDURE .
- Disconnect negative cable from battery or auxiliary jumper terminal.
- Squeeze retainer tabs together and pull fuel tube/quick-connect fitting assembly off of fuel tube nipple. The retainer will remain on fuel tube.