5. Monitor The O2 Sensors
With the engine running.
With the DRB III(R), actuate the Air Pump Relay.
Monitor the voltage on both front O2 sensors.
Does the O2 sensor voltage for both sensors drop to less than 0.1 volts?
- Yes >> Go To 12
- No >> Remove the Switchover Valve for the affected bank and inspect for damage or restrictions. If no problems are found, replace the Switchover Valve. See EMISSIONS CONTROL article.