LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Chrysler >> 2004 >> Intrepid SXT >> Repair and Diagnosis >> Quick Lookups >> Common Specs & Procedures >> Starting System >> Starter >> Service Specifications
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Service Specifications

STARTER APPLICATIONS

Model Type
Concorde, Intrepid & 300M
  2.7L Melco
  3.5L Nippondenso
STARTING SYSTEM SERVICE SPECIFICATIONS

Application Specification
Cranking Amperage Draw(1) 150-280 Amps
No-Load Test At 11 Volts
  Maximum Amps
    Melco 2.7L (2)
    Nippondenso 3.5L (2)
  Minimum RPM
    Melco 2.7L (2)
    Nippondenso 3.5L (2)
Power Rating
  Melco 2.7L 1.4 Kw
  Nippondenso 3.5L 1.4 Kw
(1) With engine at normal operating temperature. High viscosity oil, extreme cold temperatures, or an engine with tight piston ring-to-cylinder clearance will increase amperage draw.
(2) Information is not available from manufacturer.