LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Chrysler >> 2005 >> 300 Base >> Repair and Diagnosis >> Electrical >> Charging Systems >> Charging System >> Generator >> Removal >> 2.7L
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Charging System: Generator: Removal: 2.7L

  1. Disconnect negative battery cable.
    Fig 1: GENERATOR WITHOUT BELT
    GC0015629Courtesy of DAIMLERCHRYSLER CORP.
  2. Remove generator drive belt. Refer to COOLING .
  3. Disconnect generator field circuit plug.
  4. Remove B+ terminal nut and wire.
    Fig 2: LOWER BOLTS
    GC0015630Courtesy of DAIMLERCHRYSLER CORP.
  5. Remove 2 lower mounting bolts.
    Fig 3: UPPER BOLT
    GC0015631Courtesy of DAIMLERCHRYSLER CORP.
  6. Remove upper bolt.
    Fig 4: REMOVAL/INSTALL GENERATOR
    GC0015632Courtesy of DAIMLERCHRYSLER CORP.
  7. Remove generator.