Charging System: Generator: Removal: 5.7L
WARNING:
DISCONNECT NEGATIVE CABLE FROM BATTERY BEFORE REMOVING BATTERY OUTPUT WIRE (B+ WIRE) FROM GENERATOR. FAILURE TO DO SO CAN RESULT IN INJURY OR DAMAGE TO ELECTRICAL SYSTEM.
- Disconnect negative battery cable at battery.
- Remove generator drive belt. Refer to COOLING for procedure.
- Raise and support vehicle.
- Unsnap plastic insulator cap from B+ output terminal.
- Remove B+ terminal mounting nut at rear of generator. Disconnect terminal from generator.
- Disconnect field wire connector at rear of generator by pushing on connector tab.
- Remove generator support bracket nut (4) and bolt (3). Remove support bracket (1).
- Remove 2 generator mounting bolts (1).
- Remove generator (2) from vehicle.