Set Conditions
- Set Condition:
The oxygen sensor signal voltage is below 1.5 volts for 3 seconds after starting engine. One Trip Fault. Three good trips to turn off the MIL.
The oxygen sensor signal voltage is below 1.5 volts for 3 seconds after starting engine. One Trip Fault. Three good trips to turn off the MIL.