LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Chrysler >> 2006 >> Sebring GTC >> Repair and Diagnosis >> Electrical >> Charging Systems >> Charging System >> Charging >> Specifications >> Generator
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Charging System: Charging: Specifications: Generator

Type Engine Minimum Test Amperage
DENSO 2.0L 135 Amp
DENSO 2.4L 135 Amp
DENSO 2.7L 135 Amp
Test Specification:
1. Engine RPM : 2500 RPM +/-20 RPM
2. Voltage Output : 14.0 V +/- 0.5 V
3. Field Current : 5 amps +/- 0.1 amps

Part number is located on the side of the generator.