INSTALLATION - Upstream 1/1, 2/1 2.7L
The engines uses two heated oxygen sensors, one in each exhaust manifold. See Figure.
- After removing the sensor, the exhaust manifold threads must be cleaned with an 18 mm X 1.5 + 6E tap. If reusing the original sensor, coat the sensor threads with an anti-seize compound such as Loctite 771- 64 or equivalent. New sensors have compound on the threads and do not require an additional coating.
- Use a Special tool #8439 to install oxygen sensor. Tighten the sensor to 28 N.m (20 ft. lbs.) torque.
- Connect the heated oxygen sensor electrical connector.
- Install the air cleaner box.
- Install the negative battery cable.