P0325-Knock Sensor 1 Circuit Low: Notes
- When Monitored : With the Engine at operating temperature, engine speed greater than 2000 RPM, load greater than 40%, and Anti-Knock control not active.
- Set Condition : Lower limit: Knock Sensor voltage is less than 0.10 volts. Upper limit: Knock Sensor voltage is greater than 4.98 volts.
| Possible Causes |
| KNOCK SENSOR SIGNAL CIRCUIT OPEN |
| KNOCK SENSOR SIGNAL CIRCUIT SHORT TO GROUND |
| KNOCK SENSOR SIGNAL CIRCUIT SHORT TO VOLTAGE |
| SENSOR GROUND CIRCUIT OPEN |
| SENSOR GROUND CIRCUIT SHORT TO GROUND |
| SENSOR GROUND CIRCUIT SHORT TO VOLTAGE |
| KNOCK SENSOR SIGNAL CIRCUIT SHORT TO SENSOR GROUND CIRCUIT |
| KNOCK SENSOR |
| POWERTRAIN CONTROL MODULE |
For a complete Powertrain Control Module Circuit Diagram, refer to SCHEMATICS AND DIAGRAMS .