Oxygen Sensor Bank No. 1 Sensor No. 2
The post-Heated Oxygen Sensor (H02S) represents exhaust oxygen output voltage past catalytic converter. This voltage remains inactive, or voltage will appear lazy within a range of 100 mv (lean exhaust) and 900 mv (rich exhaust) when operating in a Closed Loop.