BACKPRESSURE Transducer
Disconnect and plug the output (EGR) side of transducer. Disconnect and remove transducer from vehicle. Apply 1-2 lbs. of regulated air pressure to transducer backpressure port. See Figure . Apply at least 12 in. Hg of vacuum to input port. Replace transducer if it will not hold vacuum.