ISC Motor Operation Test (1.5L)
Disconnect ISC motor connector. Connect four 1.5-volt DC batteries (6 volts total) between terminals No. 1 and 2 of ISC motor connector to operate ISC motor. See Figure . If motor does not operate, replace ISC servo assembly.