LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Eagle >> 1990 >> Talon Base, Automatic >> Repair and Diagnosis >> Engine Performance >> System >> Engine Controls - System/Component Tests >> Air Induction System >> Turbochargers >> Wastegate Solenoid Valve Test
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Wastegate Solenoid Valve Test

  1. Wastegate solenoid valve is located on air cleaner assembly. Disconnect wastegate solenoid valve electrical connector and White vacuum hose.
  2. Connect a hand held vacuum pump to wastegate solenoid valve fitting from which White vacuum hose was connected. Apply vacuum. Vacuum should hold. If vacuum does not hold, replace wastegate solenoid valve. If vacuum holds, go to next step.
  3. With wastegate solenoid valve electrical connector disconnected, apply battery voltage to wastegate solenoid valve terminals. Apply vacuum with hand held vacuum pump. Vacuum should not hold. If vacuum holds, replace wastegate solenoid valve. If wastegate solenoid valve does not hold vacuum, go to next step.
  4. Using an ohmmeter, check wastegate solenoid valve resistance. Connect ohmmeter leads between wastegate solenoid valve terminals. Ohmmeter should read 36-44 ohms at 68°F (20°C). If resistance is not within specification, replace wastegate solenoid valve.