Airflow Sensor
- Airflow sensor is located inside air cleaner assembly. Disconnect airflow sensor electrical connector. Using an ohmmeter, measure resistance between airflow sensor connector terminals No. 4 and 6 (non-turbo models), or terminals No. 6 and 8 (turbo models). See Fig 1
.
- Resistance should be approximately 6000 ohms at 32°F (0°C), 2700 ohms at 68°F (20°C) and 400 ohms at 176°F (80°C). Note that as temperature increases, resistance decreases.
- If airflow sensor resistance is not as specified or if resistance remains unchanged, replace airflow sensor.
Courtesy of CHRYSLER MOTORS.