NO RESPONSE Message
- Connect DRB-II to another vehicle. If DRB-II displays NO RESPONSE message again, DRB-II or cable adapter are faulty. Substitute to find faulty component. If message screen does not display NO RESPONSE, DRB-II and cable adapter are functioning properly. Go to next step.
- Turn ignition off. Disconnect DRB-II. Using an ohmmeter, check Pink wire for continuity between SBEC connector terminal No. 25 and engine diagnostic connector. If continuity does not exist, repair open in Pink wire.
- If continuity exists, check Light Green wire for continuity between SBEC connector terminal No. 45 and engine diagnostic connector. If continuity does not exist, repair open in Light Green wire.