Verification Procedure VER-1 - Verification Of Repairs
NOTE:
For connector terminal identification, see CONNECTOR IDENTIFICATION
. For appropriate wiring diagram, see WIRING DIAGRAMS
at end of article.
- Reconnect all previously disconnected components and connectors. Using DRB-II, calibrate Automatic Temperature Control (ATC) doors, if any work has been done on ATC system. Ensure all repairs have been made.
- Turn ignition off, then back on. Using DRB-II, erase fault codes. Fully operate system that was malfunctioning by turning switch on, opening door, etc. If system operates properly, repair is complete. If system does not operate properly, go to TEST 1A.