Test 7D - Short To Battery
NOTE:
For connector terminal identification, see CONNECTOR IDENTIFICATION
. For appropriate wiring diagram, see WIRING DIAGRAMS
at end of article.
Using DRB-II in ohmmeter mode, check OTIS connector system ground circuit (Black/Light Green wire). If resistance is more than 5 ohms, repair open circuit in Black/Light Green wire. Perform VERIFICATION PROCEDURE VER-1. If resistance is less than 5 ohms, replace OTIS. Perform VERIFICATION PROCEDURE VER-1.