Catalyst Monitoring System

DESCRIPTION 

The Catalyst Monitoring system consists of the following components:

OPERATION 

The State of Change (SOC)  catalyst monitor uses the signals from both the Upstream and Downstream Oxygen (O2) Sensors to detect aging of the catalyst. The Upstream O2 Sensor slow response monitor runs simultaneously to determine if the sensor signal is plausible. A pass/fail determination is made on the O2 Sensor slow response diagnostic before a catalyst determination is made to prevent a false fail of the catalyst monitor. These monitors are intended to determine when the O2 Sensor and catalyst systems have deteriorated to the point that tailpipe emissions exceed the appropriate malfunction limit.

CATALYTIC CONVERTER:  Inside the Catalytic Converter, the gases flow through a dense ceramic honeycomb structure coated with the catalysts. The honeycomb structure allows the gases to touch a larger area of catalyst at once, so they are converted more quickly and efficiently. The three way catalysts work to reduce tailpipe emissions.

The Catalytic Converter operates most efficiently when the engine is operated within a narrow band of air/fuel ratios near the stoichiometric point, such that the exhaust gas composition oscillates between rich (excess fuel) and lean (excess oxygen). The Upstream O2 Sensor feedback is used to maintain this optimal air/fuel ratio. The Downstream O2 Sensor feedback is used to monitor the efficiency of the Catalytic Converter.

O2 SENSORS 

Switching (4-wire) O2 Sensor Operation 

Wide-band O2 Sensor Description:  The wide-band O2 Sensor operates differently than traditional O2 Sensors. The wide-band O2 Sensor tip consists of two cells that provide different functions, a measurement chamber and a detection chamber with pumping capabilities. The oxygen pumping function is the ability to pump oxygen into or out of the measurement chamber depending on the level of oxygen in the measurement chamber. This function provides the wide-band sensing capabilities and is critical for proper oxygen measurement. The O2 Sensor Reference circuit provides a common bias supply to both the O2 Sensor Signal and the O2 Sensor Pump Cell Current circuits.