Fuel Shutoff Solenoid Valve
Solenoid is energized when ignition switch is in "ON" position. Ground is supplied by ECA. During deceleration and when ignition is off, ECA removes ground circuit causing spring loaded solenoid to close, restricting fuel flow in the idle circuit.