Act, ECT & Vat Sensor Specifications
NOTE:
For resistance test, measure resistance across sensor terminals.
ECT, ACT & VAT SENSORS RESISTANCE & VOLTAGE SPECIFICATIONS (EXCEPT 2.2L PROBE)
| Sensors °F (°C) | Specifications Volts (K Ohms) | |
|---|---|---|
| ECT & ACT (Except 2.2L Probe) | ||
| 248 (120) | 0.27 (1.18) | |
| 230 (110) | 0.35 (1.55) | |
| 212 (100) | 0.46 (2.07) | |
| 194 (90) | 0.60 (2.80) | |
| 176 (80) | 0.78 (3.84) | |
| 158 (70) | 1.02 (5.37) | |
| 140 (60) | 1.33 (7.70) | |
| 122 (50) | 1.70 (10.97) | |
| 104 (40) | 2.13 (16.15) | |
| 86 (30) | 2.60 (24.27) | |
| 68 (20) | 3.07 (37.30) | |
| 50 (10) | 3.51 (58.75) | |
| VAT | ||
| 248 (120) | 0.38 (0.11) | |
| 230 (110) | 0.46 (0.14) | |
| 212 (100) | 0.56 (0.19) | |
| 194 (90) | 0.76 (0.25) | |
| 176 (80) | 0.95 (0.33) | |
| 158 (70) | 1.19 (0.44) | |
| 140 (60) | 1.49 (0.60) | |
| 122 (50) | 1.84 (0.83) | |
| 104 (40) | 2.23 (1.18) | |
| 86 (30) | 2.65 (1.70) | |
| 68 (20) | 3.07 (2.50) | |
| 50 (10) | 3.46 (3.77) | |
ECT & VAT SENSORS (PROBE 2.2L)
| Temperature °F (°C) | Voltage | (1) Resistance Ohms | ||
|---|---|---|---|---|
| -4 (-20) | 4.70 | 10-20 | ||
| 32 (0) | 3.40 | 4-7 | ||
| 68 (20) | 2.50 | 2-3 | ||
| 104 (40) | 2.00 | 0.9-1.3 | ||
| 140 (60) | 1.20 | 0.4-0.7 | ||
| 176 (80) | 0.70 | 0.2-0.4 | ||
|
||||