Test 8, Isolate EDIS Module/Pip Fault
With key off, connect EDIS diagnostic cable positive lead to battery positive. Set DVOM to 20-volt AC scale. Hold EDIS diagnostic cable PIP push button down. Crank engine, and measure voltage breakout box pins No. J43 (PIP E) and J7 (BAT -).