Intermittent Simulation
To reproduce the conditions creating an intermittent fault, use the following methods:
- Lightly vibrate components.
- Heat component.
- Wiggle or bend wiring harness.
- Spray component with water.
- Remove/apply vacuum source.
Monitor circuit/component voltage or resistance while attempting to simulate intermittent. If engine is running, monitor for self-diagnostic codes. See appropriate TESTS W/CODES article in the ENGINE PERFORMANCE Section. Use the results to identify a faulty component or circuit.
NOTE:
For information on connecting test equipment, see appropriate TESTS W/CODES
article in the ENGINE PERFORMANCE Section.