Static Timing
- Remove fast idle bracket and solenoid from injection pump. Using Pump Mounting Wrench (T83T-9000-B), loosen nuts holding injection pump to pump mounting adapter. Install Rotating Wrench (T83T-9000-C) on front of pump, and rotate to align timing mark on pump mounting flange with timing mark on pump mounting adapter. See Fig 1.
- Align timing marks to within .030". Remove rotating wrench and tighten nuts to 84 INCH lbs. (9.5 N.m). Install fast idle bracket and solenoid.
Courtesy of FORD MOTOR CO.