Continuity Check
Disconnect ABS fail-safe relay. Set VOM on 20-k/ohm scale. At ABS fail-safe relay, measure and record resistance between terminals "c" and "g". If resistance is greater than 10,000 ohms, go to PINPOINT TEST MMR-6 . If resistance is less than specified, replace ABS fail-safe relay.
CAUTION:
When applying voltage, connect POSITIVE jumper wire to terminal "h" on ABS fail-safe relay.