Ground Check
Disconnect hydraulic actuation assembly. Using VOM at 2-pin motor connector, measure resistance between Black wire and ground. If resistance is less than 5 ohms, service Red/Yellow wire between ABS fail-safe relay and hydraulic actuation assembly. If resistance is greater than 5 ohms, service Black wire to ground.